<LOGO>
FM Transmitter Measurement Report
Created: 2026-01-29 22-06-45
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
89.40 MHz 5/5, 48 dBuV ISKELMA
Pilot RDS Phase Difference
6.4 kHz 3.0 kHz -85 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
10 kHz 66 kHz 18960 0,0686
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
3,6 dBr 5,49 dBr 6,6 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"ISKELMA " 62AD 9 (Varied) 1 0 1 1 --:--
RT
-
AF EON
89.4, 92.5, 95.0, 100.1 MHz -
FM Scope Max at: 66 kHz MIN: 10 kHz % above 76 kHz: 0,0686 Acquired: 2026/01/29 22.05.40 Total samples: 18960 Equivalent time: 0:15:48 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 1000 2000 3000
FM Scope MAX: 6,6 dBr MIN: 3,6 dBr AVE: 5,49 dBr % above 12,2 dBr: 0,0 Last value: 5,5 dBr (2026/01/29 22.05.40) 21.52 21.54 21.56 21.58 22.00 22.02 22.04 0 2 4 6 Pm [dBr]